Cooling tower packing

750mm & 950mm Cooling Tower Fill with 20mm Pitch for Application-Specific Configurations

WhatsApp QR Code WhatsApp QR
WeChat QR Code WeChat QR
Product Description

750mm & 950mm Cooling Tower Fill with 20mm Pitch for Application-Specific Configurations

Cooling tower fill selection involves more than choosing a suitable width. Corrugation geometry, material, pack dimensions, and installation method all need to match the cooling tower design and operating requirements. Our 750mm and 950mm wide cooling tower fill is available with a 20mm pitch and 90° corrugation angle, providing defined structural options for industrial cooling tower projects.

Manufactured in PVC, CPVC, or PP, this fill can be customized in length and thickness to meet different assembly requirements. Both glue bonding and hanging installation methods are available, allowing customers to specify the product according to their equipment configuration and maintenance needs.

Product Specifications

Product TypeCooling Tower Fill
Width750mm, 950mm
LengthCustomizable
ThicknessCustomizable
Pitch20mm
Corrugation Angle90°
MaterialPVC, CPVC, PP
Connection MethodGlue or hang

Structural Specifications for Cooling Tower Fill Selection

The pitch and corrugation angle are important structural parameters when specifying cooling tower fill. They define aspects of the sheet geometry and should be considered alongside the tower's airflow arrangement, water distribution, available installation space, and operating conditions. The 20mm pitch and 90° corrugation angle of this product provide a clear starting point for matching fill specifications to the intended assembly.

Actual cooling performance depends on the complete fill geometry, fill depth, airflow, water loading, and operating conditions. Buyers should therefore evaluate the product as part of the overall cooling tower design rather than relying on a single dimensional parameter to predict efficiency.

Width and Dimension Customization

The 750mm and 950mm width options support projects with different fill layout requirements. Customized length and thickness provide additional flexibility when preparing fill packs for new cooling towers or replacing existing media.

For replacement applications, accurate measurements of the existing fill pack and supporting structure are particularly important. For OEM projects, confirming the required dimensions against equipment drawings helps ensure that the selected fill fits the intended configuration.

Material Options for Different Operating Conditions

PVC, CPVC, and PP are available to accommodate different material selection requirements. The appropriate option depends on circulating water chemistry, operating temperature, and the properties of the specific material grade. Selecting a suitable material helps align the fill specification with the service environment and the expected maintenance cycle.

Where water quality or operating temperature presents particular challenges, these conditions should be reviewed before confirming the material. Material compatibility should be assessed together with the cooling tower's actual operating requirements.

Installation Options for Different Fill Assemblies

This cooling tower fill is available for glue bonding or hanging installation. The preferred method depends on the fill pack design, support arrangement, and the requirements of the cooling tower structure. Confirming the connection method before production helps coordinate the supplied fill with the intended assembly and installation procedure.

Customized Fill Supply for Industrial Cooling Systems

Our 750mm and 950mm wide cooling tower fill combines defined structural specifications with customizable dimensions and multiple material options. It is suitable for consideration in OEM equipment production, industrial cooling tower refurbishment, and replacement fill sourcing where the specified configuration matches the application requirements.

When requesting a quotation, please provide the required dimensions, material preference, connection method, and relevant operating conditions. This information helps establish a suitable product specification for your cooling tower project.

Contact us to discuss your cooling tower fill requirements and customized supply options.

User Reviews
Michael Schneider
Michael Schneider
Cooling System Engineer

We purchased PVC film fill and drift eliminators for our industrial cooling tower project. The quality of the cooling tower fill was consistent, and the dimensions matched our requirements perfectly. The supplier provided professional technical support during the selection process and delivered the products on schedule. We appreciate their reliable communication and stable product performance.

Ahmed Al Mansouri
Ahmed Al Mansouri
Mechanical Equipment Consultant

We used their cooling tower packing materials for a commercial cooling system upgrade project. The products arrived well packed and without damage. The supplier showed good knowledge of cooling tower applications and helped us choose suitable fill materials according to our operating conditions.

Park Min Jae
Park Min Jae
Project Procurement Specialist

We have cooperated with this manufacturer for cooling tower fill materials for our replacement projects. Their cross flow fill and corrugated fill products have stable quality and good forming accuracy. They understand industrial requirements and can provide customized solutions according to different cooling tower models.

Anan Chaiwat
Anan Chaiwat
Maintenance Manager

Our cooling tower needed replacement fill media due to long-term operation. We selected their PP fill media after technical discussion. The new cooling tower fill improved water distribution and helped restore the cooling efficiency of our system. The ordering process was smooth, and the team was very responsive to our questions.

Hot Products
Fully Customizable Counter-flow Cooling Tower Fill
1. Fully Customizable Counter-flow Cooling Tower Fill Over
300/600mm Dual-width Counter-flow Fill
1. 300/600mm Dual-width Counter-flow Fill Introduction Ef
12mm Pitch Cooling Tower Fill
1. 12mm Pitch Cooling Tower Fill Introduction Compact Sur
750/950mm Dual-width Cross-flow/Counter-flow Fill
1. 750/950mm Dual-width Cross-flow/Counter-flow Fill Overv
FAQ
Do you offer cooling tower fill installation support?
We can assist with technical guidance and recommend experienced service partners worldwide. On-site support from our engineers may also be arranged according to project requirements.
What Is The Production Schedule For Cooling Tower Fill Media?
Standard production time is about 5–7 weeks after order approval, depending on specifications and customization needs. Flexible arrangements can be discussed for urgent project schedules.
Does your cooling tower fill media meet fire resistance requirements?
Yes, standard PVC cooling tower fill media is designed with flame-resistant properties for common operating conditions. Additional material options can be discussed according to specific project requirements.
What operating conditions can your cooling tower fill media support?
Our cooling tower fill media is designed for different cooling environments with reliable heat transfer performance. Customized fill designs can be developed according to specific tower structures and project operation requirements.