15mm Pitch Film Fill for High-Efficiency Cooling Tower Systems

Our Film Fill is developed for cooling tower systems where a defined corrugated surface, compact 15mm pitch, and flexible fill dimensions are required. With widths available from 1220mm to 1800mm, this product provides a configurable fill format for high-efficiency cooling tower projects and replacement applications.

Compact Pitch for Film Fill Design

The fill features a 15mm pitch and a 5.5° angle, forming a consistent corrugated surface throughout the fill sheets. This product configuration is intended for customers specifying a compact-pitch film fill for their cooling tower media arrangement.

The defined pitch and angle provide a clear basis for specifying the fill product, while customized dimensions allow the overall fill configuration to be adapted to individual project requirements.

Wide Width Selection

Available widths include 1220mm, 1320mm, 1520mm, 1600mm, 1620mm, 1700mm, and 1800mm. This range covers several wide-format options for customers working with different fill section dimensions.

The length and thickness are customizable, allowing the finished product to be specified beyond the available width range. This is particularly useful when the required fill dimensions are determined by a specific cooling tower design or existing fill pack.

PVC, CPVC and PP Options

Customers can choose from PVC, CPVC, and PP materials when specifying this cooling tower fill. These material options provide flexibility for different project requirements while retaining the same basic 15mm pitch and 5.5° product configuration.

The final material selection can therefore be combined with the required width, length, and thickness to establish a complete fill specification.

Flexible Fill Pack Connection

The product supports both glue and hang connection methods. This gives customers flexibility when assembling the fill sheets into the required fill pack and allows the connection method to follow the intended construction arrangement.

Made for Specific Cooling Tower Requirements

High-efficiency cooling tower projects are not always based on one universal fill dimension. For this reason, this product combines a defined 15mm pitch and 5.5° angle with multiple width choices and customized length and thickness.

This configuration provides a practical product basis for customers who need to specify cooling tower fill according to their own tower dimensions, fill pack design, or replacement requirements.

Product Specifications

Connection MethodGlue or Hang
Width1220mm, 1320mm, 1520mm, 1600mm, 1620mm, 1700mm, 1800mm
LengthCustomized
ThicknessCustomized
Pitch15mm
MaterialPVC, CPVC, PP
Angle5.5°

Flexible Film Fill for Efficiency-Focused Projects

Combining a 15mm pitch, 5.5° angle, wide width selection, customizable dimensions, and PVC, CPVC, or PP material options, this Film Fill provides a configurable product solution for efficiency-focused cooling tower applications. Contact us with your required fill dimensions and material preference for a product specification matched to your project.

User Reviews
Michael Schneider
Michael Schneider
Cooling System Engineer

We purchased PVC film fill and drift eliminators for our industrial cooling tower project. The quality of the cooling tower fill was consistent, and the dimensions matched our requirements perfectly. The supplier provided professional technical support during the selection process and delivered the products on schedule. We appreciate their reliable communication and stable product performance.

Ahmed Al Mansouri
Ahmed Al Mansouri
Mechanical Equipment Consultant

We used their cooling tower packing materials for a commercial cooling system upgrade project. The products arrived well packed and without damage. The supplier showed good knowledge of cooling tower applications and helped us choose suitable fill materials according to our operating conditions.

Park Min Jae
Park Min Jae
Project Procurement Specialist

We have cooperated with this manufacturer for cooling tower fill materials for our replacement projects. Their cross flow fill and corrugated fill products have stable quality and good forming accuracy. They understand industrial requirements and can provide customized solutions according to different cooling tower models.

Anan Chaiwat
Anan Chaiwat
Maintenance Manager

Our cooling tower needed replacement fill media due to long-term operation. We selected their PP fill media after technical discussion. The new cooling tower fill improved water distribution and helped restore the cooling efficiency of our system. The ordering process was smooth, and the team was very responsive to our questions.

Hot Products
Fully Customizable Counter-flow Cooling Tower Fill
1. Fully Customizable Counter-flow Cooling Tower Fill Over
300/600mm Dual-width Counter-flow Fill
1. 300/600mm Dual-width Counter-flow Fill Introduction Ef
12mm Pitch Cooling Tower Fill
1. 12mm Pitch Cooling Tower Fill Introduction Compact Sur
750/950mm Dual-width Cross-flow/Counter-flow Fill
1. 750/950mm Dual-width Cross-flow/Counter-flow Fill Overv
FAQ
Do you offer cooling tower fill installation support?
We can assist with technical guidance and recommend experienced service partners worldwide. On-site support from our engineers may also be arranged according to project requirements.
What Is The Production Schedule For Cooling Tower Fill Media?
Standard production time is about 5–7 weeks after order approval, depending on specifications and customization needs. Flexible arrangements can be discussed for urgent project schedules.
Does your cooling tower fill media meet fire resistance requirements?
Yes, standard PVC cooling tower fill media is designed with flame-resistant properties for common operating conditions. Additional material options can be discussed according to specific project requirements.
What operating conditions can your cooling tower fill media support?
Our cooling tower fill media is designed for different cooling environments with reliable heat transfer performance. Customized fill designs can be developed according to specific tower structures and project operation requirements.
Send Us a Message
Code
Need help? Chat with us!